title: "TDS - HYDROPHASE-APS Gen2"
url: https://stacklist.com/card/a598c7a8-ebdc-41f1-8d19-e7c414e13d93
stack: https://stacklist.com/stack/42c6c47f-5e5b-4e51-a9ea-ca638a9282b9
summary: "Hydrophase APS is a dual-function primer and sealer product by Formulated Materials that prevents moisture absorption and enhances adhesion for flooring underlayments across various substrates. With low-odor, fast-drying properties and blue tinting for visibility, it ensures proper curing and surface durability while maintaining environmental compliance with VOC content below 50 g/L."
tags: "hydrophase-aps, primer-sealer, flooring-underlayment, moisture-control, concrete-substrate, low-voc, technical-data-sheet"
key_entities: "Formulated Materials, LLC (organization), Hydrophase APS (technology), Modified Styrene/Acrylic Latex (technology), Oklahoma City, OK (location), moisture-resistant bond (concept), self-leveling materials (concept)"
classification: "reference"
content_hash: "sha256:84d68a16c5ed701fb3f60d68edaa6fdb19bfe118f410894002e15e62573ab1ea"
acp_version: "0.2"
token_counts_approximate: 2149
visibility: public
agent_accessible: true
status: "final"
---

# TDS - HYDROPHASE-APS Gen2

Data sheets are subject to change without notice. For latest revision, visit www.formulatedmaterials.com. 
TECHNICAL DATA SHEET 
Hydrophase ® APS 1. Product Name 
Hydrophase ® APS 
2. Manufacturer 
Formulated Materials, LLC 
3010 NW 149th St., SUITE 100 
Oklahoma City, OK 73134 
Tech Services : (844) 405-3676 
www.formulatedmaterials.com 
www.formulated.info 
3. Product Description 
HydroPhase ® APS 
As a Primer: APS forms a protective barrier that prevents porous 
substrates from absorbing moisture from underlayments. By controlling 
moisture retention, APS ensures a uniform curing process, reducing the 
risk of premature drying, shrinkage, cracking, or surface weakness. 
This moisture-resistant bond improves adhesion and enhances the 
long-term performance of self-leveling materials over concrete, wood, 
gypsum, adhesive residues, and metal substrates. 
As a Sealer: When applied over cured underlayments, APS increases 
abrasion resistance and surface durability, protecting the underlayment 
and preparing it for the installation of finished flooring. Sealing the 
surface prevents dusting and moisture absorption, creating a stable 
base for adhesives and floor coverings. 
With a low-odor, fast-drying formula tinted blue for easy application 
visibility, HydroPhase ® APS ensures consistent, high-quality results in 
both priming and sealing applications, optimizing the performance and 
longevity of underlayments and levelers. 
Key Features 
• As a Primer: Enhancing Bond & Ensuring Proper Curing 
– Prevents uneven curing – Forms a protective barrier that reduces 
substrate moisture absorption, preventing premature drying, shrink - 
age, and cracking. 
– Creates a strong bond – Ensures superior adhesion between the 
subfloor and poured underlayments for long-term performance. 
– Deep penetration & porosity reduction – Penetrates the substrate 
to reduce porosity and improve underlayment coverage 
and consistency. 
– High pH tolerance – Can be applied over freshly placed concrete 
without compromising adhesion or performance. 
• As a Sealer: Preparing Underlayments for Flooring Installation 
– Improves surface hardness – Enhances the durability and abrasion 
resistance of cured underlayments and levelers. 
– Moisture control – Seals the surface to prevent moisture absorption, 
reducing dusting and improving compatibility with 
floor coverings. 
– Fast drying – Ready for underlayment or flooring installation in 60 
minutes or less, depending on conditions.without compromising 
adhesion or performance. 
• Ease of Use & Environmental Compliance 
– Visual application indicator – Tinted to a translucent blue for easy 
verification of coverage. 
– Creates a strong bond – Ensures superior adhesion between the 
subfloor and poured underlayments for long-term performance. 
– Easy application – Can be applied with a roller or sprayer for efficient 
installation. 
– Low odor, low VOC (<50 g/L) – Environmentally compliant and safe 
for use in occupied spaces. 
Suitable Substrates 
• Use on freshly placed concrete cured for 72 hours and free 
of surface water. 
• Existing concrete, no minimum surface profile required. 
• Lightweight or structural concrete, wood, adhesive residues, 
or gypsum. 
• May be used directly under moisture or alkaline-sensitive 
floor coverings. 
• Structurally sound wooden subfloors. 
Recommended Uses 
• Multifamily Construction (Apartments, Condominiums, Hotels). 
• Residential and Single-Family Homes. 
• Commercial Office Spaces. 
• Renovation of existing wood or concrete structures. 
Product Composition 
• Modified Styrene/Acrylic Latex. 

Data sheets are subject to change without notice. For latest revision, visit www.formulatedmaterials.com. 
TECHNICAL DATA SHEET 
Hydrophase ® APS Technical Chart 
Property Test Method Results 
Base Chemistry Modified Styrene/Acrylic Copolymer 
Physical State Liquid 
Color Translucent Blue 
Solids By Volume Total Coverage 23% 
VOC Content >1 g/L 
Dry Time 30 – 60 min per coat 
Working Temperature 45 ° – 100 ° F (7 ° – 38 ° C) 
Total Coverage Undiluted – 150-200 sf per gallon 
Diluted 3:1 – 600-800 sf per gallon 
ASTM Test Standard 
F710 Standard Practice for Preparing Concrete Floors to Receive 
Resilient Flooring 
F3191 
Standard Practice for Field Determination of Substrate 
Water Absorption (Porosity) for Substrates to Receive 
Resilient Flooring 
D2697 Standard Test Method for Determining the Volume of Nonvolatile 
Matter in Clear or Pigmented Coating 
4. Technical data 
Applicable Standards 
Environmental Considerations 
Formulated Materials is dedicated to environmental responsibility in 
product development and manufacturing processes. When used per 
applicable guidelines, this product may contribute to LEED ® certification. 
5. Instructions 
General Surface Prep 
Ensure the surface is clean, dry and structurally sound. Repair any 
cracks, spalling, or unstable areas. Remove dust, dirt, oil, grease, and 
contaminants. Use mechanical methods (grinding, sanding) if needed. 
Verify moisture levels meet product requirements. Address excessive 
moisture if necessary. Maintain recommended temperature and humidity. 
Avoid extreme conditions. Perform a final check to clear debris and 
confirm the surface meets all preparation guidelines before application. 
Installation of Product 
Always read the Safety Data Sheet (SDS) for full precautionary 
instructions before use. 
Tools Required 
• Broom or blower – for surface preparation. 
• Soft bristle broom - for application over porous substrates. 
• 3/8" Paint roller w/extension pole – for even application. 
Application 
Site Conditions 
• Apply only when temperature is between 40° F and 100° F, and 
Relative Humidity is below 90%. 
Apply 
• Agitate product by hand or slow-speed mixing to ensure a uniform 
consistency before application. 
• Porous Substrates 
– Dilute 3:1 (Water:APS) before applicatio. 
– Pour diluted primer on the surface and broom evenly over 
the substrate. 
– Use a soft-tip broom only. 
– DO NOT apply by sprayer or roller over porous substrates. 
• Non-Porous Substrates 
– Use a 3/8” paint roller to apply an even coat to all areas receiving 
the underlayment or leveler. 
• Use As A Sealer 
– Make certain underlayment is clean and contaminate-free. 
– Dilute with water to a 3:1 ratio (Water:APS). 
– Ready to receive flooring goods in approximately 60 minutes. 
• Apply at 150 – 800 sq ft per gallon of diluted mixture, depending 
on surface profile and porosity. 
Product Limitations 
• Ambient, substrate, and product temperatures must be greater 
than 40° F and less than 100° F. 
• Do Not Allow the Product To Freeze. Never use a product that 
has been subject to freezing or storage below 40° F. 
• Dilute APS with clean, potable water. 
• Porous substrates and aggressively profiled surfaces may lower 
product coverage. 
• Never apply over surfaces where water may be seen glistening 
on the surface or where water may be mopped up with a dry 
rag or paper towel. 
• Perform a small test patch to determine product suitability. 
• Limitations not to be construed as all inclusive. 
Packaging 
• 5 Gal pail / 36 pails per pallet. 

TECHNICAL DATA SHEET 
Hydrophase ® APS © Formulated Materials • Rev. 07/2026 
Formulated Materials, LLC 
3010 NW 149th St., SUITE 100 
Oklahoma City, OK 73134 
Tech Services : (844) 405-3676 
www.formulatedmaterials.com 
www.formulated.info 
6. Product Warranty 
For details and complete warranty information, visit 
www.formulatedmaterials.com. 
7. Product Maintenance 
Properly installed products do not require ongoing maintenance. 
8. Technical Services Information 
For Technical Services, contact Formulated Materials at (844) 405-3676. 
Check for Readiness 
• APS Dries Clear when ready for application of underlayment, leveler, 
or flooring. 
• Dry Time: Approximately 60 minutes, depending on temperature 
and humidity. 
• Touch Test: The surface should be tacky but not transfer to your 
hand. 
Clean Up 
• Clean tools with water immediately after application. 
• If necessary, mineral spirits or similar agents may clean any cured 
material. 
Storage & Handling 
• Store between 40 ° F and 100 ° F in a sealed container. 
• Shelf life is 12 months from manufacture when stored properly. 
Health Precautions 
• Follow the manufacturer’s Safety Data Sheets (SDS) and safety 
protocols for PPE. 
Conformance to Building Codes 
Always read the Safety Data Sheet (SDS) for full precautionary 
instructions before use. 
For additional technical support, contact Formulated Materials 
or visit www.formulatedmaterials.com.