title: "Section 5: FM 10-Year Warranty Requirements"
url: https://stacklist.com/card/832e9a64-fde5-4959-97ba-82d7ca795d82
stack: https://stacklist.com/c/technology/stack/ccc8a635-1426-4960-958d-568d07671c5e
summary: "FM 10-Year Warranty Requirements specify coverage for waterproofing membrane systems (SP1 primer + S60 sheet) with detailed voiding conditions and submittal requirements. The specification includes warranty eligibility criteria, required documentation, and recommended spec language for Part 1 to ensure owners receive proper warranty protection."
tags: "warranty, waterproofing, specification, fm-certified, construction-documents, submittal-checklist, flood-test"
key_entities: "SP1 primer (technology), S60 sheet membrane (technology), DM2 drainage mat (technology), FM 10-Year Warranty (concept), flood test (concept), TTP detail (concept), FM (organization)"
classification: "reference"
content_hash: "sha256:02a42473e53e51748af02892c13e1a22cdcf31d32305a0be0ba119f90d5e962c"
acp_version: "0.2"
token_counts_approximate: 510
visibility: public
agent_accessible: true
status: "final"
---

# Section 5: FM 10-Year Warranty Requirements

Section 5: FM 10-Year Warranty Requirements 
What the warranty covers, what voids it, and how to spec it so the owner actually gets it. 
What the FM 10-Year Warranty Covers 
Waterproofing membrane system: SP1 primer + S60 sheet membrane 
Transition conditions installed per applicable TTP detail 
Railing pocket conditions installed per TTP-6 
Labor and materials for repair of warranted failures 
What Voids the Warranty 
| Voiding Condition | How to Prevent in the Spec | |---|---|---| | Non-FM-certified installer | Require FM
applicator certification in Part 1 | | Unapproved product substitution | Name SP1 and S60 explicitly, no
substitutions | | Penetrations through cured membrane | Division 07 and 05 coordination language | | No
flood test documentation | Require flood test log in Part 3 | | Missing submittal package | List required
submittals in Part 1 | | Topping placed before flood test | Sequence requirement in Part 3 execution | 
Submittal Checklist for Warranty Application 
[ ] SP1 primer product data sheet 
[ ] S60 membrane product data sheet 
[ ] DM2 drainage mat product data sheet 
[ ] Applicable TTP detail drawings 
[ ] FM-certified applicator documentation 
[ ] Signed flood test log with photographs 
[ ] Completed FM warranty application form 
[ ] Project address, GC contact, and install dates 
Spec Language for Part 1: Warranty 
8/8/26, 1:10 AM Section 5: FM 10-Year Warranty Requirements 
https://md2pdf.netlify.app 1/2 

1.3 WARRANTY
A. Upon project completion, provide FM 10-Year System Warranty to owner.
B. Warranty eligibility requires:
1. Installation by FM-certified applicator
2. SP1 primer, S60 membrane, DM2 drainage mat assembly
3. All transitions per applicable FM TTP detail
4. Passing 24-hour flood test with documented log
5. Complete submittal package delivered to FM before warranty issuance
C. Submit warranty application to FM within 30 days of substantial
completion of waterproofing scope. 
8/8/26, 1:10 AM Section 5: FM 10-Year Warranty Requirements 
https://md2pdf.netlify.app 2/2