---
title: "ELEVATION® T-Bar_7.10.26 Gen2"
url: https://stacklist.com/card/6a5f1af7-beba-4453-ad01-329c42571e38
stack: https://stacklist.com/c/business/stack/6ef6e379-b702-4156-8fa8-00346fb192a1
summary: "Elevation® T-Bar is a premium 6063 aluminum alloy edge stop designed for concrete balcony applications as part of the Elevation® Waterproofing system. It provides a pour stop for wear layers and maintains a weep system for moisture removal, with installation support from a network of licensed dealers."
tags: "aluminum-t-bar, concrete-balcony, waterproofing-system, edge-stop, 6063-aluminum, installation-guide, technical-data"
key_entities: "Formulated Materials, LLC (organization), Elevation® T-Bar (technology), 6063 Aluminum Alloy (technology), Oklahoma City, OK (location), Waterproofing System (concept), Concrete Balcony Edge Stop (concept)"
classification: "reference"
content_hash: "sha256:43eba7a01114a263d8c5d3b6d2df16294f956f441bbd0d747ec1626ff70ee4a7"
acp_version: "0.2"
token_counts_approximate: 1500
visibility: public
agent_accessible: true
status: "final"
---

# ELEVATION® T-Bar_7.10.26 Gen2

Data sheets are subject to change without notice. For latest revision, visit www.formulatedmaterials.com. 
TECHNICAL DATA SHEET 
Elevation ® T-Bar 1. Product Name 
Elevation ® T-Bar 
2. Manufacturer 
Formulated Materials, LLC 
3010 NW 149th St., SUITE 100 
Oklahoma City, OK 73134 
Tech Services : (844) 405-3676 
www.formulatedmaterials.com 
www.formulated.info 
3. Product Description 
Elevation ® T-Bar Concrete Balcony Edge Stop is a premium-quality, 
6063 aluminum alloy T-Bar approved for use with all ELEVATION ® 
Waterproofing systems. The product is manufactured to our 
specifications, resulting in greater strength and consistency of dimension, 
gauge, and finish when compared to many regionally available products. 
Properly installed, Elevation ® T-Bar provides a pour stop for the wear 
layer on a waterproofed balcony and maintains a weep system to ensure 
proper removal of moisture trapped beneath the wear layer. 
Key Features 
• Higher quality, better finish, and increased durability explicitly 
designed for use in balcony applications 
• Increased strength reduces the risk of damage during transport and 
before application of the wear layer 
• Wider nail flange eases installation 
• Available in anodized, primed and powder coated finishes 
• Consistent dimensions assure proper pour depth 
• Backed by a full system warranty and manufacturer support 
• Installed by a network of technically trained licensed dealers 
Where to Use 
• Multifamily construction 
• Apartments 
• Hotels 
• Condominiums 
• Single-family homes 
• Commercial office spaces 
• Renovation of aging wood frame or concrete structures 
Product Composition 
• 6063 Aluminum 
Product Limitations 
• The T-Bar is one component of an entire Elevation Waterproofing 
System and will perform as described, but ultimate performance is 
dependent upon the design, components, and implementation of 
the waterproofing system 
• Limitations not to be construed as all inclusive 
Packaging 
• 10' and 12' Lengths Packed in bundles of 40 or 80 depending 
on size 
• 1.5", 2.0", 2.5" & 3.0" Pour Depths 
• Mill Finish or Anodized (Clear, Brown, and Black) 
4. Technical Data 
Technical Chart 
Property Results 
Material 6063 Aluminum 
Thickness 0.058" (1.47mm) 
Height 3.875" (98.4mm) 
Nail Flange 3.000" (76.2mm) 
Temper T5 
Tensile Strength (min) 17 ksi 
Environmental Considerations 
Formulated Materials is dedicated to environmental responsibility in 
product development and manufacturing processes. 

Formulated Materials, LLC 
3010 NW 149th St., SUITE 100 
Oklahoma City, OK 73134 
Tech Services : (844) 405-3676 
www.formulatedmaterials.com 
www.formulated.info © Formulated Materials • Rev. 06/2026 
TECHNICAL DATA SHEET 
Elevation ® T-Bar 
5. Instructions 
General Surface Prep 
Ensure the surface is structurally sound. Repair any unstable areas. 
Address excessive moisture if necessary. Avoid extreme conditions. 
Perform a final check to clear debris and confirm the surface meets all 
preparation guidelines before application. 
Installation of Product 
Always read the Safety Data Sheet (SDS) for full precautionary 
instructions before use. 
Tools Required: 
• Tape Measure 
• Snips or Angle Grinder 
• Hammer 
• 1.5" – 2.0" Roofing Nails 
Surface Prep 
• Apply SP1 Primer as recommended and allow it to dry 
Application 
• The T-Bar is installed after the installation of the waterproofing system 
• Measure and Cut: 
– Measure the distance along the balcony face between the mounting 
plates of the TTPs and cut the T-Bar accordingly. 
– T-Bar should extend over the T-Bar Termination Pocket base plate 
and into the trough to ensure proper shingling and drainage are 
maintained. 
– Material can be cut with angle grinder (using appropriate grinding 
wheel) or heavy duty metal shears. Proper PPE should be used at all 
times when cutting or shaping. 
• Address Exterior Corners (if applicable): 
– Measure from each TTP to the corner and add 2" to your total length. 
– Mark the corner location, adding 1" from the desired corner. 
– Cut a “V” into the nailer flange of the T-Bar and notch the top flange. 
– Snip the kick-out on the bottom-front-face of the T-Bar for relief 
when folding at 90. 
– Fold the metal at the corner with moderate pressure and trim the 
ends for proper alignment. 
• Add Spacer Shims: 
– Place Elevation ® Spacer Shims every 14" along the bottom of the 
T-Bar nailer flange that rests on the deck to create consistent 
spacing for the weep system. 
– Overhang T-Bar by 1/4" to identify where to drive fasteners. 
– Also run spacer shim down the back-side of the down-leg of the 
T-Bar to continue the weep system. 
• Fasten the T-Bar: 
– Position the T-Bar over the Spacer Shims, ensuring the weep gap 
remains unobstructed. 
– Nail the T-Bar to the deck through the shims, securing stability. 
– Apply a dab of Elevation SM2 Lap Sealant over nail heads to 
reinforce waterproofing. 
Go to www.formulatedmaterials.com and formulated.info for more 
detailed installation information. 
Storage & Protection 
• This product is temperature stable and weather resistant. 
• Care should be taken when handling, particularly full bundles, to 
avoid bending or crushing exposed edges 
• Elevation T-bar products should be stored in an environment 
protected from the elements 
Health Precautions 
• Follow all local safety regulations, including OSHA Section V: 
Chapter 4 for Fall Protection in Construction 
• Always review the full label and Safety Data Sheet (SDS) for detailed 
precautionary instructions before use. 
Conformance to Building Codes 
Installation must comply with all applicable local, state, and federal 
codes, regulations, and industry standards. 
6. Product Warranty 
For details and complete warranty information, visit 
www.formulatedmaterials.com. 
7. Product Maintenance 
Properly installed products do not require ongoing maintenance. 
8. Technical Services Information 
For Technical Services, contact Formulated Materials at (844) 405-3676.
